Product description The Dentistry Base Polymer Search Stability tester is an instrument used to eva
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
The Dentistry Base Polymer Search Stability tester evaluates color stability of dental base polymers (used in restorations like dentures) under varied conditions (light, temp, humidity). It records initial and subsequent color of samples to assess changes. This helps dentists and technicians choose better materials, improving repair effectiveness and durability, and aids manufacturers in enhancing product performance.
The applications of color stability testers for dental materials are mainly reflected in the following aspects:
Quality Control: Helping manufacturers screen materials with resistant color changes and improve product durability.
Clinical Decision Making: Assisting dentists in selecting aesthetically pleasing and durable restorative materials, reducing revision rates.
Compliance and Certification: Meeting the testing requirements of industry standards such as YY/T 0631-2008.
These testers assess the color changes of dental materials under simulated environmental conditions, such as light, temperature, and humidity. During the test, the dental material sample is placed in the tester and exposed to predetermined environmental conditions. The tester records the initial color of the sample and remeasures the color at certain time intervals. By comparing the initial color and the subsequent measured color, the color stability of the dental material can be evaluated.
YY0270.1-2011: Dentistry - Base polymers - Part 1: Denture base polymers
YY/T0631-2008: Dental materials - Determination of colour stability
ASTM C1442: Standard Practice for Conducting Tests on Sealants Using Artificial Weathering Apparatus
ASTM C1501: Standard Test Method for Color Stability of Building Construction Sealants as Determined by Laboratory Accelerated Weathering Procedures
ASTM D3424: Standard Practice for Evaluating the Relative Lightfastness and Weatherability of Printed Matter
ASTM D5071: Standard Practice for Exposure of Photodegradable Plastics in a Xenon Arc Apparatus
ASTM D6695: Standard Practice for Xenon-Arc Exposures of Paint and Related Coatings
ASTM G151: Standard Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources
ASTM G155: Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
COLIPA in-vitro UVA (2011): Method for in vitro determination of UVA protection
EPA/ASTM E896: Standard Test Method for Conducting Aqueous Direct Photolysis Tests
GB/T 8427: Textiles - Tests for color fastness - Color fastness to artificial light: Xenon arc fading lamp test
GB/T 16422: Plastics -- Methods of exposure to laboratory light sources -Part 2: Xenon-arc lamps
ICH Q1B: Q1B Photostability Testing of New Drug Substances and Products
ICH Q5C: Stability testing of Biotechnological / Biological products
ISO 4049: Dentistry -- Polymer-based restorative materials
ISO 7491: Dental materials -- Determination of colour stability
ISO 4892-1: Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance
ISO 4892-2: Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc sources
The dental material color stability tester has the following features:
Simulated Environmental Conditions: By simulating the light, temperature, and humidity conditions of the oral cavity, the sample undergoes accelerated aging treatment, and its color change is measured periodically to evaluate the material's color stability.
Ease of Operation: The instrument is user-friendly, easy to operate, and convenient to maintain.
High Sensitivity: Color change is measured using spectrophotometry, with repeatability accuracy reaching ΔE*ab ≤ 0.015. ensuring sensitive detection of color changes.
Environmental Stress Simulation: By setting specific periods (e.g., several hours to several days), changes in material color stability are observed.
Color Stability Evaluation Indicators: Auxiliary parameters include yellowness index (YI) and whiteness index (WI), used to quantify specific color shifts.
These features make the dental material color stability tester of significant application value in the research, development, production, and clinical application of dental materials.
| Project | Details |
|---|---|
| Control System | PLC |
| Operation Interface | Color touch screen with Chinese-English switching |
| Light Source | Illuminance of 150.000 lx with an accuracy deviation not exceeding 10% |
| Color Temperature Range | 5000K - 10000K |
| Filter | Light transmittance greater than 90% |
| Test Chamber | Water temperature range: 0 - 99°C; Test temperature: 37°C; Adjustable water temperature with temperature display |
| Clamp | 304 stainless steel clamp with an outer diameter of 50MM and a thickness of 0.5MM |
| Polyurethane Film | Thickness ranging from 50μm to 0.5MM |
| Built-in Dial Indicator of the Equipment | Range: 0 - 25.5MM; Precision: 0.01MM |
| Standard | 15L constant-temperature tank with a temperature range of 0 - 99°C |
The main accessories of a dental material color stability tester include the following, each playing a crucial role in the testing process:
Sample clamp: Typically made of 304 stainless steel, it can hold samples with a diameter of 50mm, ensuring stable fixation during testing.
Filter: A standard ultraviolet filter has a filtration efficiency of less than 1% for light wavelengths below 300nm and a transmittance of more than 90% for light wavelengths above 370nm. It is used to filter out unwanted light waves, ensuring the accuracy of test results.
Xenon lamp: As the standard light source, an air-cooled, full solar spectrum long-arc xenon lamp has a color temperature in the range of 5000~10000K and a lifespan of approximately 1500 hours, providing stable and near-natural light illumination conditions for testing.
Blackboard thermometer: Used to monitor and record temperature changes during testing, ensuring the testing environment meets standard requirements.
Illuminance meter: Used to measure and adjust the illuminance received by the sample, ensuring the illuminance is within the range of 150000lx±15000lx, meeting testing standards.
Circulating water bath system: Includes a circulating water tank and water pipes, used to maintain the sample water bath temperature within the range of 37±1℃ (or 37±5℃) to simulate the oral cavity temperature environment.
Standard wrenches: Such as 17-19 size wrenches, used for installing and adjusting fasteners in the equipment.
Other accessories: Depending on the specific equipment model and configuration, may also include product certificates, instruction manuals, delivery notes, acceptance slips, and other documents, as well as auxiliary accessories such as power cords and water pipes.
The operation method of a dental material color stability tester includes the following steps:
Prepare the equipment and materials, including the tester, the dental material to be tested, a standard light source, and a standard color chart.
Place the dental material to be tested under the standard light source for pretreatment to simulate the lighting conditions in actual use.
Place the dental material to be tested on the sample holder of the tester and adjust the position and angle of the tester to ensure the accuracy and reliability of the test results.
Select a suitable standard color chart for comparison with the color of the dental material to be tested.
Set the test parameters, such as test time and light source type.
Start the test and record the color change data during the test.
Process and analyze the data to calculate key parameters such as the color difference value and color difference change rate of the dental material to be tested.
Compare the test results with the requirements of actual applications to evaluate the color stability performance of the dental material to be tested in actual use.
Qinsun Instruments Co., LTD is a professional laboratory testing instrument manufacturer in China,Have been focusing on laboratory instrument R&D more than 30 years and have rich industry experience,Based on international testing standards,We are also the instrument supplier for BV SGS laboratory,We provide one-stop solutions for lab instruments,Free Training and Turn-Key Service,Products exported all over the world,Offer 36 month warranty and are a trustworthy partner.
Company Phone
+86-21-6420 0566
Working hours
Monday to Friday
Mobile phone:
13816217984
Email:
info@qinsun-lab.com