Detailed Product DescriptionProduct Introduction:0.1/RON; 0.1/MON; 0.1/CIResponse Time:1SMeasur
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
Product Introduction: | 0.1/RON; 0.1/MON; 0.1/CI | Response Time: | 1S |
---|---|---|---|
Measurement Results: | LCD Display, Storage And Printing | Power Supply: | AC (220±10%) V (50±1) Hz |
Working Environment: | 10℃~35℃; Relative Humidity ≤85% | Weight: | 15kg |
Dimensions: | 330mm×240mm×230mm(With Sensor) | ||
Highlight: | Octane Cetane Number Tester Astm D613 Oil Analysis Testing Equipment |
Octane cetane number gauges are commonly used for octane number field analysis of power gasoline, in contrast to the motor method and the research method (RON and MON),Correspondingly, it can also be applied to the cetane number analysis of diesel oil.
GB/T503-2015. GB/T5487-2015. ASTMD2700 (motor method), ASTMD2699 (research method), ASTM D613
(1) Aviation gasoline: 86.0~105.0/MON
(2) Vehicle gasoline
GB: 55.0~115.0/RON
Country 5: 65.0~115.0/RON
Blending: 75.0~120.0/RON Heterogeneous: 85.0~120.0/RON
Lightweight: 50.0~85.0/MON Aromatics: 90.0~120.0/RON
Ethanol: E93: 92.0~95.0/RON; E97: 95.0~99.0/RON
Judgment: 60.0~120.0/RON
(3) Vehicle diesel: 25~75/CN (Cetane Number); 20~80/CI (Cetane Index)
Aviation gasoline: ≤± 1.5/MON;
Motor gasoline: ≤±1.5/RON; ≤±1.5/MON
Vehicle diesel: ≤±2.5/CN; ≤±2.5/CI
Regression sample retest: ≤±0.5/RON; ≤±0.5/MON
Regression sample measurement: ≤±1.5/RON; ≤±1.5/MON
Calibration accuracy: ≤±0.2/RON ≤±0.2/MON
Reproducibility: ≤±0.5/RON;
Repeatability: ≤±0.2/RON
Disclaimer: The above content is for reference and communication only among industry insiders, and does not guarantee its accuracy or completeness. According to relevant laws and regulations and the regulations of this website, units or individuals who purchase related items should obtain valid qualifications and qualification conditions.