Welcome to Qinsun Instruments Co., Limited.

Rapid thermal conductivity tester

info@qinsun-lab.com Get Quote

  • Compliant with standards:X0sTextile Testing Instruments, Testing Equipment Manufacturer

    GB 10297-1998.X0sTextile Testing Instruments, Testing Equipment Manufacturer

    Applicable scope:X0sTextile Testing Instruments, Testing Equipment Manufacturer

    Measure the thermal conductivity of non-metallic solid materials.X0sTextile Testing Instruments, Testing Equipment Manufacturer

    Product Description:X0sTextile Testing Instruments, Testing Equipment Manufacturer

    The IMKD-A series rapid thermal conductivity meter developed by our company has the characteristics of simple structure, rapid measurement, and high measurement accuracy.X0sTextile Testing Instruments, Testing Equipment Manufacturer

    Product features:X0sTextile Testing Instruments, Testing Equipment Manufacturer

    1. Short measurement time: During the measurement process, the material of the test piece undergoes less denaturation and deformation, and the measured values are closer to the true values;X0sTextile Testing Instruments, Testing Equipment Manufacturer

    2. Easy operation: All adopt microcomputer intelligent control, and operators do not need special training and can directly operate on duty;X0sTextile Testing Instruments, Testing Equipment Manufacturer

    3. Wide testing range: effectively covering non-metallic materials and low thermal conductivity metal materials;X0sTextile Testing Instruments, Testing Equipment Manufacturer

    4. High measurement accuracy and wide application range: widely used in various fields such as architecture, energy, environmental protection, chemical industry, medical treatment, energy conservation, etc;X0sTextile Testing Instruments, Testing Equipment Manufacturer

    Technical parameters:X0sTextile Testing Instruments, Testing Equipment Manufacturer

    1. Power supply AC220V plusmn; 10%, 50HzX0sTextile Testing Instruments, Testing Equipment Manufacturer

    2. Temperature rise range (0-80) ℃X0sTextile Testing Instruments, Testing Equipment Manufacturer

    3. Temperature resolution 0.01 ℃X0sTextile Testing Instruments, Testing Equipment Manufacturer

    4. Temperature measurement accuracy 0.1 ℃X0sTextile Testing Instruments, Testing Equipment Manufacturer

    5. Thermal conductivity measurement range le; 2W/(m middot; K)X0sTextile Testing Instruments, Testing Equipment Manufacturer

    6. Measurement error plusmn; 5%X0sTextile Testing Instruments, Testing Equipment Manufacturer

    7. Maximum measurement time of 300sX0sTextile Testing Instruments, Testing Equipment Manufacturer

    8. Laboratory temperature (23 plusmn; 2) ℃X0sTextile Testing Instruments, Testing Equipment Manufacturer

    9. Laboratory humidity (40-60)% RHX0sTextile Testing Instruments, Testing Equipment Manufacturer

    10. Test specimen size: rectangular: not less than 40mm x 80mm x 114mm or cylindrical: cross-sectional diameter not less than 80mm, length not less than 114mmX0sTextile Testing Instruments, Testing Equipment Manufacturer

    11. Number of test pieces: 2 piecesX0sTextile Testing Instruments, Testing Equipment Manufacturer

Get a Quote