The critical radiation flux is the main parameter to investigate the fire hazard of the flooring material. It characterizes the combustion spread capacity of the flooring material burned under the condition of external heat radiation. It is an important indicator in the grading system of flooring materials used as building products.rPrTextile Testing Instruments, Testing Equipment Manufacturer
rPrTextile Testing Instruments, Testing Equipment Manufacturer
Floor material thermal radiation board test meets the requirements of ISO9239-1,2 and GB / T 11785-2005. In the test chamber, the floor covering material is burned in a certain thermal radiation environment to measure the critical thermal radiation value. It can also be used to measure the critical radiation value of attic floor cellulose insulation material.rPrTextile Testing Instruments, Testing Equipment Manufacturer
rPrTextile Testing Instruments, Testing Equipment Manufacturer
Structure Features>rPrTextile Testing Instruments, Testing Equipment Manufacturer
1, All structural parts are made of stainless steel, beautiful, corrosion-resistant, durable.rPrTextile Testing Instruments, Testing Equipment Manufacturer
2, Radiation heat source is the porous ceramic heat radiation plate 300mmX450mm, tilt 30deg;.rPrTextile Testing Instruments, Testing Equipment Manufacturer
3, The United States imported calorimeter 50KW / ㎡.rPrTextile Testing Instruments, Testing Equipment Manufacturer
4, The igniter diameter is 0.7mm, 19 / EA, at the position of 60 degrees from the bottom of each center.rPrTextile Testing Instruments, Testing Equipment Manufacturer
5, the standard plate is made of uncoated calcium silicate board at the thickness of 20 plusmn; 1mm, density of 850 plusmn; 100kg / msup3;, size 1050X250mm.rPrTextile Testing Instruments, Testing Equipment Manufacturer
6, Small stainless steel ignition nozzle assists sample ignition.rPrTextile Testing Instruments, Testing Equipment Manufacturer
7, Imported flow control valve, precise control of propane flow.rPrTextile Testing Instruments, Testing Equipment Manufacturer
8, A blower to provide air source. The test gas is mixed through the Venturi mixed gas.rPrTextile Testing Instruments, Testing Equipment Manufacturer
rPrTextile Testing Instruments, Testing Equipment Manufacturer
Optical System>rPrTextile Testing Instruments, Testing Equipment Manufacturer
1, The optical system contains a light source of the 2900 plusmn; 100 K color temperature incandescent lamp. Light source is received by the silicon photodiode, equipped with a optical path test shutter, for the use of 0% and 100% calibration.rPrTextile Testing Instruments, Testing Equipment Manufacturer
2, Imported photovoltaic module measures the degree of light attenuation. The system automatically calculates the light transmission and generates light transmission curve, which is free to print.rPrTextile Testing Instruments, Testing Equipment Manufacturer
rPrTextile Testing Instruments, Testing Equipment Manufacturer
Thermal Radiation System>rPrTextile Testing Instruments, Testing Equipment Manufacturer
1, Thermal radiation pyrometer accuracy of plusmn; 0.5℃, about 1.4m away from the radiation panel.rPrTextile Testing Instruments, Testing Equipment Manufacturer
2, Radiation pyrometer sensitivity keeps constant in the wavelength range of 1um ~ 9um.rPrTextile Testing Instruments, Testing Equipment Manufacturer
3, High-performance K-armored thermocouple diameter of 3.2mm, with insulation and non-grounded hot junction, located at the position of 25mm under the roof the chamber and 100mm behind the flue wall .rPrTextile Testing Instruments, Testing Equipment Manufacturer
4, the heat flow of the heat radiation panel surface shall be adjusted by a radiation pyrometer with a detectable diameter range of 250mm and a black body temperature range within 480℃~530℃.rPrTextile Testing Instruments, Testing Equipment Manufacturer
4. Measure the heat flux from the heating panel to 110mm~910mm within the deviation at 110mm interval.rPrTextile Testing Instruments, Testing Equipment Manufacturer
5, in the error range, measured from the radiator to 110mm ~ 910mm within the heat flux, the interval is 110mm.rPrTextile Testing Instruments, Testing Equipment Manufacturer
rPrTextile Testing Instruments, Testing Equipment Manufacturer
Control System>rPrTextile Testing Instruments, Testing Equipment Manufacturer
1.Standard control cabinet, embedded with an integrated 10.2quot; touch screen.rPrTextile Testing Instruments, Testing Equipment Manufacturer
2. Sound alarm and alarmed accident displayrPrTextile Testing Instruments, Testing Equipment Manufacturer
3. USB / RS232 serial port on the control cabinet can connect desktop/notebook computer for operation control and free print of test reports.rPrTextile Testing Instruments, Testing Equipment Manufacturer
4. Programmable logic controller (PLC) control system:rPrTextile Testing Instruments, Testing Equipment Manufacturer
rPrTextile Testing Instruments, Testing Equipment Manufacturer
Specifications:>rPrTextile Testing Instruments, Testing Equipment Manufacturer
Power: AC220Vplusmn;10%,50Hz;rPrTextile Testing Instruments, Testing Equipment Manufacturer
Max. power:5KW;rPrTextile Testing Instruments, Testing Equipment Manufacturer
Dimension:Ltimes;Wtimes;H(2.2times;1.2times;2.4)m;rPrTextile Testing Instruments, Testing Equipment Manufacturer
Weight:350Kg.
Get a Quote