Surface point-to-point resistance tester

info@qinsun-lab.com Get Quote

  • Main use:yrbTextile Testing Instruments, Testing Equipment Manufacturer

    The point-to-point resistance tester/fabric surface resistance tester is used to measure the point-to-point resistance of fabrics such as carpets, films, insulation materials, etc., to test the anti-static performance of textile test materials.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    Testing standards:yrbTextile Testing Instruments, Testing Equipment Manufacturer

    GB120114-2009yrbTextile Testing Instruments, Testing Equipment Manufacturer

    Main features:yrbTextile Testing Instruments, Testing Equipment Manufacturer

    1. It mainly consists of two parts: a flat electrode device and a high resistance meter;yrbTextile Testing Instruments, Testing Equipment Manufacturer

    2. The resistance value is directly displayed by numbers, with high accuracy, fast display, good stability, and convenient reading;yrbTextile Testing Instruments, Testing Equipment Manufacturer

    3. Built in timer, automatically locks the reading after 15 seconds.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    Technical parameters:yrbTextile Testing Instruments, Testing Equipment Manufacturer

    1. Adopting a highly integrated 31/2-digit digital display.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    2. Range: 1 times; 105 Omega;~1.999 times; 1013 Omega;yrbTextile Testing Instruments, Testing Equipment Manufacturer

    3. Test voltage is DC100V or customizedyrbTextile Testing Instruments, Testing Equipment Manufacturer

    4. Working environment temperature: 20 ℃plusmn; 2 ℃, humidity: 35% plusmn; 10% RHyrbTextile Testing Instruments, Testing Equipment Manufacturer

    5. Test accuracy: plusmn; 5% when le; 1012 Omega;; When1012 Omega;, it is 20%.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    Detection steps:yrbTextile Testing Instruments, Testing Equipment Manufacturer

    1. The high-voltage output end and measurement input end of the instrument are respectively connected to two electrodes (the shielding end is not used). The conductive rubber is placed on the surface of the test sample at a certain distance according to the standard requirements, and the electrodes are placed on the conductive rubber.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    2. Set the multiplier (range) switch to the low gear. The low magnification of this instrument is times; 105 Omega;, and resistance measurement must start from the low range. This is because the measured object may have a large distributed capacitance, which may cause charging current to harm the highly sensitive input terminal of the instrument at the moment of measurement.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    3. Turn the high-voltage (zero calibration) selection switch to the quot;discharge zero calibrationquot; position above 100V.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    4. Turn on the power switch of the instrument.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    5. Depending on the specific situation, turn on the Filter 1 or Filter 2 switch.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    6. Zero calibration - Confirm that the high voltage (zero calibration) selection switch has been set to the quot;discharge zero calibrationquot; position above 100V, adjust the zero calibration knob (8) to make the instrument reading. 000.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    7. Turn on the timer switch.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    8. The charging time required for a 100V test voltage is very short. Quickly turn the high voltage (zero calibration) selection switch to 100V, apply the test voltage to the tested object, start the resistance measurement, and start timing. After 15 seconds, the quot;Hquot; character is displayed in the lower middle of the left side of the display screen, and the displayed value is automatically locked.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    9. Record this value. Turn the switch to the quot;discharge calibration zeroquot; position, at which point the measured voltage is disconnected and the discharge circuit is connected. After about 15 seconds, the tested device is fully discharged, and the operator can only contact the high voltage end and the measurement end.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    10. After an interval of 3-5 minutes, move the electrode after the residual charge on the tested sample is fully released, repeat the above steps, and proceed to the next set of data measurement.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    11. After completing all tests, turn off the power switch, turn off the timer switch, and turn off the filter 1 and filter 2 switches; Turn the high-voltage (zero calibration) selection switch to the quot;discharge zero calibrationquot; position above 100V; Set the multiplier (range) switch to the low gear position; Organize and properly place the test sample holder, power cord, electrodes, and conductive rubber.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    Notes:yrbTextile Testing Instruments, Testing Equipment Manufacturer

    1. Before starting the operation, the instrument power should be in the off position. After the previous measurement is completed, an internal discharge time of about 30 seconds should be passed to ensure that the operator is not subjected to high-voltage electric shock;yrbTextile Testing Instruments, Testing Equipment Manufacturer

    2. Built in battery and external power supply, only one power supply method can be selected;yrbTextile Testing Instruments, Testing Equipment Manufacturer

    3. Please place in a dry and ventilated place when not in use;yrbTextile Testing Instruments, Testing Equipment Manufacturer

    4. When not in use for a long time, please remove the battery from the battery box to avoid battery leakage and corrosion of the instrument;yrbTextile Testing Instruments, Testing Equipment Manufacturer

    5. Non professional maintenance personnel are not allowed to open the instrument cover to prevent electric shock caused by high voltage inside the machine. Opening the cover without authorization and disassembling or changing the internal components of the instrument may result in losing the instruments warranty qualification or increasing repair costs.yrbTextile Testing Instruments, Testing Equipment Manufacturer

    6. It is strictly prohibited to use corrosive fluxes such as hydrochloric acid and solder paste to weld measuring wires, connectors, or internal components of instruments, in order to avoid irreparable leakage faults.yrbTextile Testing Instruments, Testing Equipment Manufacturer