The air-cooled xenon lamp aging test chamber uses xenon arc lamps that can simulate full sunlight spectrum to reproduce destructive light waves in different environments. It can provide corresponding environmental simulation and accelerated testing for scientific research, product development, and quality control. In a few days or weeks, outdoor hazards that occur for months or even years can be reproduced. The Qinsun air-cooled xenon lamp aging test chamber has good repeatability and simulates natural aging technology for light and climate resistance tests, which helps to establish new standards for durability testing of textile materials. It can be widely used in plastics, packaging materials, automotive coatings, interiors and plastic components, paints, coatings and pigments, printing inks, optoelectronic products, and industrial geotextiles. The Atlas Xenontest 150S+air-cooled xenon lamp aging testing machine meets almost all universal textile standards.
Product Usage:>
The use of xenon arc lamps that can simulate full sunlight spectra to reproduce destructive light waves in different environments can provide corresponding environmental simulation and accelerated testing basis for scientific research, product development, and quality control. To evaluate the light and weather resistance of certain materials under the action of high-temperature light sources, aging tests are conducted on material samples exposed to xenon arc lamp illumination and thermal radiation. They are mainly used in automobiles, coatings, rubber, plastics, pigments, adhesives, fabrics, etc
Compliant with standards:>
AATCC TM16H-1998 TM169.ASTM G151 G155 D6695.ISO 105-B02 105-B04 12040 4892-1. JASO M346. Mamp;S C9 C9A.
Product parameters:>
Temperature range: RT+10 ℃~70 ℃
Humidity range: 65% to 98% RH
Blackboard temperature: 63 ℃~100 ℃
Temperature uniformity: le; 2.0 ℃ (in the dark)
Temperature fluctuation: plusmn; 0.5 ℃ (in the dark)
Humidity deviation:+2, -3% RH
Spray nozzle aperture: Ф 0.8mm
Rainwater pressure: 0.12-0.15Mpa
Rainfall time: 1-999M, adjustable for continuous rainfall
Spray cycle: 18min/102min or 12min/48min (spray time/stop time)
Light cycle: 1-999h, m, s continuously adjustable
Sample tray size: 450 x 720mm
Distance between sample holder and lamp: 230-280mm
Wavelength: 290-800nm
Radiation intensity: le; 550W/㎡
Xenon lamp power: 2.5KW x 3 units=7.5KW
Heating power: 3.0KW
Humidification power: 2.0KW
Outer box material: High quality A3 steel plate electrostatic spraying
Inner box material: imported high-grade stainless steel SUS304
Temperature and humidity controller: quot;Taiwan Weilunquot; touch screen+quot;German Siemensquot; PLC module
Temperature and humidity sensor: PT100 platinum resistance thermometer
Standard configuration: 3 lamp tubes, 1 layer of sample holder
Safety protection: compressor overpressure, compressor overload, water shortage protection, fan motor overheating, overall equipment overheating, overall equipment under phase/reverse phase
The overall equipment is protected by timed leakage protection, water shortage protection, and automatic shutdown after fault alarm
Power supply voltage: AC380V plusmn; 10% 50Hz
Power: 14.5KW
Usage environment: 5 ℃~+28 ℃ le; 85% RH
Test environment:>
1. The above data were all measured under good ventilation conditions in an operating environment with a temperature of 25 ℃
2. Non standard customization of air-cooled xenon lamp climate resistance test chambers can be made according to user specific test requirements