Double plate thermal conductivity tester integrated water bath thermostat equipment, all measurement and control are used computer control. Mainly testing plastic, rubber, glass, fiberboard, benzene board, extruded board, foam concrete, hollow glass, wood, all kinds of insulation materials such as homogeneous plate material, and can measure the pellets, bulk materials, soft materials and other Thermal conductivity of matter. The instrument can be widely used in heat and insulation materials production enterprises, the relevant quality inspection departments and units, institutions of higher learning and research institutes and other scientific research units.TnZTextile Testing Instruments, Testing Equipment Manufacturer
TnZTextile Testing Instruments, Testing Equipment Manufacturer
Standards>TnZTextile Testing Instruments, Testing Equipment Manufacturer
IOS 10294-2008 Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation MaterialsTnZTextile Testing Instruments, Testing Equipment Manufacturer
IOS 3399-1982 Test method for thermal conductivity of plastics - Heat - resistant plate methodTnZTextile Testing Instruments, Testing Equipment Manufacturer
IOS 10801.1-2002 Thermal insulation polystyrene foamTnZTextile Testing Instruments, Testing Equipment Manufacturer
IOS 10801.2-2002 Extruded polystyrene foamTnZTextile Testing Instruments, Testing Equipment Manufacturer
IOS 3139-2005 Test method for thermal conductivity of fiber reinforced plasticsTnZTextile Testing Instruments, Testing Equipment Manufacturer
IOS 17794-2008 Flexible foam rubber and plastic insulation productsTnZTextile Testing Instruments, Testing Equipment Manufacturer
TnZTextile Testing Instruments, Testing Equipment Manufacturer
Features>TnZTextile Testing Instruments, Testing Equipment Manufacturer
Chassis is nice. Test box shell uses spray method. It has mechanical strength, anti-corrosionTnZTextile Testing Instruments, Testing Equipment Manufacturer
The device is small and the unique casters are designed to increase the flexibility of the thermometer movement.TnZTextile Testing Instruments, Testing Equipment Manufacturer
High safety performance. It not only adopts the use of circuit and refrigeration cycle independent design, but also can ensure that the electrical part of the collected data from the impact of water, and improve stability.TnZTextile Testing Instruments, Testing Equipment Manufacturer
Good performance of temperature stability and unique protection board design, can form a one-dimensional protection, so that it has no loss of temperature.TnZTextile Testing Instruments, Testing Equipment Manufacturer
Online double standard company unique technology which can calibrate the temperature, calibration system error, is accurate, fast and convenient.TnZTextile Testing Instruments, Testing Equipment Manufacturer
TnZTextile Testing Instruments, Testing Equipment Manufacturer
Technical Parameters>TnZTextile Testing Instruments, Testing Equipment Manufacturer
Items |
Parameters |
Specimen standard size |
300mm times; 300mm times; H (5 ~ 40) mm |
Specimen flatness |
0.1mm |
Thermal conductivity measurement display range |
(0.001 ~ 2.000) W / (m bull; K) |
Thermal conductivity measurement accuracy |
plusmn; 3% |
Thermal conductivity measurement Repeatability |
plusmn; 1% |
Temperature resolution |
0.01 ℃ |
Temperature control accuracy |
0.05 ℃ |
TnZTextile Testing Instruments, Testing Equipment Manufacturer
Technical Parameters>TnZTextile Testing Instruments, Testing Equipment Manufacturer
Different types of thermal conductivity tester temperature measurement range |
Model |
Cold plate temperature control interface ℃ |
Hot plate temperature control range ℃ |
IMDRY3001-I |
Room temperature - 95 ℃ |
Room temperature - 100 ℃ |
IMDRY3001-Ⅱ |
-℃ -5 ℃ - 95 ℃ |
15 ℃ - 95 ℃ |
IMDRY3001-Ⅲ |
-10 ℃ - 95 ℃ |
10 ℃ - 95 ℃ |
IMDRY3001-IV |
-15 ℃ - 95 ℃ |
5 ℃ - 95 ℃ |
IMDRY3001-V |
-20 deg; C - 95 deg; C |
0 deg; C - 95 deg; C |
IMDRY3001-Ⅵ |
-30 ℃ -95 ℃ |
-10 ℃ -95 ℃ |
IMDRY3001-VII |
-40 ℃- 95 ℃ |
-20 ℃ - 95 ℃ |
Power supply |
AC 220V plusmn; 10%, 2.5KW |
Specimen thickness |
Standard 25mm, range (5 ~ 40) mm |
Specimen thermal resistance requirements |
the thermal resistance of the specimen should not be less than 0.1 (m2 bull; K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 bull; K) / W, the accuracy does not necessarily meet the requirements. |
Clamping force |
No more than 2.5kPa |
Get a Quote
Your email address will not be published. Required fields are marked *