JG057 Mask amp; Respirator Dead Space Tester>
【Product Overview】>
The JG057 mask and respirator dead space tester is used to test fire respirators with positive dead space pressure. The test principle is determined by measuring the CO2 content of the inhaled gas. >
【Compliance with standard】 >>
GB2626-2019 etc. >
JG057 mask and respirator dead space tester 【Technical parameters】 >>
1 Working environment: CO2 gas concentration in the ambient airle;0.1%>
2. Source of carbon dioxide: volume fraction of CO2 gas (5plusmn;0.1)% >
3. CO2 flow meter: CO2 mass flow controller with analog input and output signals, flow and measurement can be automatically adjusted by computer program; flow range: 0-50 l/min, accuracy: level 2.>
4. Equipped withCO2 analyzer: range 0-12%, accuracy level 1.>
5. Anemometer, range: 0-10 m/s, accuracy: plusmn;(0.1 m). /s+5% of measured value) at measuring range (0~2m/s). >
6. The ventilation rate adjustment range is (10-40) times/min, and the tidal volume adjustment range is (0.5-3.0) L. >
7. Full power supply: AC220V, power 500W. >