NYSTextile Testing Instruments, Testing Equipment Manufacturer
YG469 Mask Bacterial Filtration Efficiency Tester>NYSTextile Testing Instruments, Testing Equipment Manufacturer
【Product Overview】>NYSTextile Testing Instruments, Testing Equipment Manufacturer
The YG469 Mask Bacterial Filtration Efficiency Tester is used to test Bacterial Filtration Efficiency (BFE) by metrology and inspection departments, research institutes, medical mask manufacturers and other relevant departments. >NYSTextile Testing Instruments, Testing Equipment Manufacturer
【Reference Standard】 >>NYSTextile Testing Instruments, Testing Equipment Manufacturer
YY/T 0969-2013, YY 0469-2011, ASTM F 2100, ASTM F 2101, EN 14683, etc. >NYSTextile Testing Instruments, Testing Equipment Manufacturer
YG469 Mask Bacterial Filtration Efficiency Tester 【Technical Parameters】>>NYSTextile Testing Instruments, Testing Equipment Manufacturer
NYSTextile Testing Instruments, Testing Equipment Manufacturer
Main Parameters>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Range Parameters>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Vacuum pump>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Oil-free rotary vane vacuum pump, maximum flow rate can reach 57L/min, equipped with muffler, stable airflow>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Aerosol generator flow control >NYSTextile Testing Instruments, Testing Equipment Manufacturer
Aerosol generator flow control uses counterMass flow control, precise control;>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Gas path sampling flow>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Anderson sampling flow 28.3 l/min, resolution: 0.1 l/min. (user configurable)>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Gas path sampling flow II>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Anderson sampling flow 28.3 L/min Resolution: 0.1 L/min (user configurable)>NYSTextile Testing Instruments, Testing Equipment Manufacturer
I, II sampling channel>NYSTextile Testing Instruments, Testing Equipment Manufacturer
equipped with a mass flow controller>NYSTextile Testing Instruments, Testing Equipment Manufacturer
I gas circuit pressure>NYSTextile Testing Instruments, Testing Equipment Manufacturer
0ndash;20 kPa, resolution: 0.01 kPa >NYSTextile Testing Instruments, Testing Equipment Manufacturer
II air path pressure>NYSTextile Testing Instruments, Testing Equipment Manufacturer
0-20 kPa, resolution: 0.01 kPa>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Spray flow meter pressure>NYSTextile Testing Instruments, Testing Equipment Manufacturer
0-300 kPa, resolution Velocity: 0.01 kPa>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Negative pressure in the aerosol chamber>NYSTextile Testing Instruments, Testing Equipment Manufacturer
0~120 Pa, resolution: 0.01 kPa>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Operating temperature>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Operating temperature>NYSTextile Testing Instruments, Testing Equipment Manufacturer
0 ~50℃>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Negative chamber pressure>NYSTextile Testing Instruments, Testing Equipment Manufacturer
0-120Pa>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Data storage capacity>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Data can be loaded via U disk*>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Mass flow controller>NYSTextile Testing Instruments, Testing Equipment Manufacturer
0~20L/min Resolution: 0.1L/min>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Speed peristaltic flowpump>NYSTextile Testing Instruments, Testing Equipment Manufacturer
(0.01~3.0)ml/min Resolution: 0.1L/min>NYSTextile Testing Instruments, Testing Equipment Manufacturer
High efficiency airFilter performance>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Particle filtration efficiency larger than 0.3 micro;m ge;99.99%>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Average mass diameter of the aerosol generator>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Average particle diameter (3.0plusmn;0.3) micro;m, geometric standard deviation le;1, 5>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Bilateral 6-Stage Anderson Gripper>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Particle Size>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Class I 7 micro;m, Class II (4.7~7) micro;m, Class III ( 3.3~4.7) micro;m class IV (2.1~3.3) micro;m class V>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Grade (1.1~2.1) micro;m class VI (0.6 ~1.1) micro;m>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Aerosol Chamber Specifications>
600mmtimes;80mmtimes;5mmL*D*T>NYSTextile Testing Instruments, Testing Equipment Manufacturer
Positive Quality Control Sampler Total Particles >NYSTextile Testing Instruments, Testing Equipment Manufacturer
(2200plusmn;500 ) cfu>NYSTextile Testing Instruments, Testing Equipment Manufacturer
YG469 Mask Bacterial Filtration Efficiency Tester>>NYSTextile Testing Instruments, Testing Equipment Manufacturer