Welcome to Qinsun Instruments Co., Limited.
2022-11-24 0 Views

Test method for fogging tester for automotive interior parts

The automotive interior parts atomization tester is suitable for interior materials such as automobiles and aircraft, such as automotive interior plastic parts, polyurethane, textiles, leather, adhesives, non-woven fabrics, thermoplastic elastomers and other materials. of volatile components. SMzTextile Testing Instruments, Testing Equipment Manufacturer

Through the atomization test of car interior decoration materials, the volatile substances in car interior decoration materials can be controlled, effectively reducing the environmental pollution in the car. Therefore, the atomization test has become an important means for automobile manufacturers and car interior decoration manufacturers to check product quality. The automotive interior parts atomization tester is a manufacturer of the atomization test instrument. QINSUN is the manufacturer Welcome to customers who need timely inquiry. SMzTextile Testing Instruments, Testing Equipment Manufacturer

SMzTextile Testing Instruments, Testing Equipment Manufacturer

The test method is as follows:SMzTextile Testing Instruments, Testing Equipment Manufacturer

DIN75201 --- refreading method, weight methodSMzTextile Testing Instruments, Testing Equipment Manufacturer

SAEJ1756---reflection method, gravimetric methodSMzTextile Testing Instruments, Testing Equipment Manufacturer

ISO6452---reflection method, gravimetric methodSMzTextile Testing Instruments, Testing Equipment Manufacturer

QB/T2728---reflection method, gravimetric method SMzTextile Testing Instruments, Testing Equipment Manufacturer

NESM0161---haze methodSMzTextile Testing Instruments, Testing Equipment Manufacturer

ES-X83231---haze method, gravimetric methodSMzTextile Testing Instruments, Testing Equipment Manufacturer

Reflection method Add 10 ± 0.1 g DIDP to the tank with a constant temperature of 100°C In the beaker, with the cooling plate at 21°C, the end result should be within 77 ± 3%. Otherwise, the test is considered failed. Users should identify the cause and retest. SMzTextile Testing Instruments, Testing Equipment Manufacturer

Gravimetric method Put 10 ± 0.1 g of DOP in a beaker soaked in a bath with a constant temperature of 100 ° C, the cooling plate is 21 ° C, and the final result should be within the range of 4.9 ± 0.25 mg lying down. Otherwise, the test is considered failed. Users should identify the cause and retest. SMzTextile Testing Instruments, Testing Equipment Manufacturer

For the haze method, there is no calibration method provided in the above standardn.