GB11158-89 Precision High temperature aging test box

GB11158-89 Precision High temperature aging test box

Release time: 2021-12-04 Hits: 393

The standard for high temperature aging test test Box structure and appearance requirements: kGuTextile Testing Instruments, Testing Equipment Manufacturer

1. The inner wall should be manufactured with heat resistance and not easy to oxidize and a certain mechanical strength; kGuTextile Testing Instruments, Testing Equipment Manufacturer

kGuTextile Testing Instruments, Testing Equipment Manufacturer

2. The thickness of the insulation material is high -temperature resistant to high temperature and has self -extinguishing performance; 3. The temperature of the external access to the site is not higher than 50 ° C; kGuTextile Testing Instruments, Testing Equipment Manufacturer

4. The heating device must not constitute the direct radiation of the test sample; kGuTextile Testing Instruments, Testing Equipment Manufacturer

5. Observation windows should be provided, and lighting devices should be provided in the studio; kGuTextile Testing Instruments, Testing Equipment Manufacturer

6. kGuTextile Testing Instruments, Testing Equipment Manufacturer

7. The sealing bar of the box door should not be easily aging, hair sticky, deformation, Lost sealing performance, and should be convenient for replacement; kGuTextile Testing Instruments, Testing Equipment Manufacturer

8. Sample racks with samples should be placed or hanging. The sample rack should have a certain mechanical strength and easy loading and unloading at high temperature conditions;

kGuTextile Testing Instruments, Testing Equipment Manufacturer

9. Instruments or devices such as temperature adjustment, instructions, records, etc. should be possessed;

kGuTextile Testing Instruments, Testing Equipment Manufacturer

10. The appearance of the coating should be smooth and smooth, and the color is uniform. There must be no dew, foaming, starting layer or scratch traces.

kGuTextile Testing Instruments, Testing Equipment Manufacturer

The calculation and evaluation of the test results of the high temperature aging test box: 1. Correct the measured temperature values according to the correction value of the test instrument; kGuTextile Testing Instruments, Testing Equipment Manufacturer

2. Use 15 test data in 30 minutes to find the height and low temperature in each test The average arithmetic value of the difference is the temperature uniformity of the temperature at the nominal temperature; the 15 test values of the central test point are higher than half of the low temperature difference between the low temperature, and the crown is ±. Volatility at temperature. kGuTextile Testing Instruments, Testing Equipment Manufacturer

3. Use 24h test data to calculate the difference between 蕞 height, low temperature and nominal temperature, respectively, kGuTextile Testing Instruments, Testing Equipment Manufacturer

High -temperature aging test box The temperature deviation of the temperature at the nominal temperature. kGuTextile Testing Instruments, Testing Equipment Manufacturer

1. The temperature control system kGuTextile Testing Instruments, Testing Equipment Manufacturer

3 1. Temperature control to PID number display instrument (Taiwan Xuanrong program table), 8 -stage temperature control, can be automatically calculated, PV/SV also displayed at the same time. Any temperature value; 2. The timer is 1 second -999 (you can choose to set the hour, minute, second) Time to cutting the heating current (alarm device) Alarm device) kGuTextile Testing Instruments, Testing Equipment Manufacturer

3. Type of temperature and circulation (K);

kGuTextile Testing Instruments, Testing Equipment Manufacturer

4. The output is 3-32V;

5. The current controller is SSR solid state relay; kGuTextile Testing Instruments, Testing Equipment Manufacturer

6. The heating material is: high temperature resistant heating pipe;

kGuTextile Testing Instruments, Testing Equipment Manufacturer

7, RT -100 ° C about 12 minutes, empty load;

8. The temperature range is room temperature to 200 ° C. Common temperature. Below 200 degrees; kGuTextile Testing Instruments, Testing Equipment Manufacturer

kGuTextile Testing Instruments, Testing Equipment Manufacturer

2. kGuTextile Testing Instruments, Testing Equipment Manufacturer

High -temperature aging test box

accuracy kGuTextile Testing Instruments, Testing Equipment Manufacturer

kGuTextile Testing Instruments, Testing Equipment Manufacturer

1, control accuracy ± 1 ℃;

2. Display analysis 1 ℃; kGuTextile Testing Instruments, Testing Equipment Manufacturer

3. The temperature distribution in the box is uniformity ± 3 ℃. 3. Power device Voltage AC 380V Three -phase Four -line kGuTextile Testing Instruments, Testing Equipment Manufacturer

Three -phase current 54 A kGuTextile Testing Instruments, Testing Equipment Manufacturer

Heating power 10kW

kGuTextile Testing Instruments, Testing Equipment Manufacturer

Total power 12 kw

kGuTextile Testing Instruments, Testing Equipment Manufacturer