Welcome to Qinsun Instruments Co., Limited.
2022-06-02 0 Views

GB/T 16921-2005X fluorescent coating thickness instrument

IOS 16921-2005X fluorescent coating thickness meter

Release time: 2022-02-09 Hits: 302

Operation mechanism: ufpTextile Testing Instruments, Testing Equipment Manufacturer

There is a certain relationship between covering the area of the unit area (if the mystery is known, it is a linear thickness) and the secondary radiation intensity. For any actual instrument system, the relationship first known that the unit area quality covers the correction standards for correction standards. If the density of the covering material is known and the actual density is given, such a standard block can give a layered linear thickness. ufpTextile Testing Instruments, Testing Equipment Manufacturer

The fluorescent intensity is the function of element atomic order . Ten more than one element, these elements will produce their own radiation characteristics. The appropriate detector system is adjusted to select one or more energy bands, so that this device can measure the surface coverage layer and simultaneously measure the thickness and composition of the surface coverage layer and some intermediate coverage layers. ufpTextile Testing Instruments, Testing Equipment Manufacturer

X fluorescent coating thickness meter The test report should include the following content: 1. The number of this standard; ufpTextile Testing Instruments, Testing Equipment Manufacturer

2. The accurate logo of the sample; ufpTextile Testing Instruments, Testing Equipment Manufacturer

3. Measurement date; ufpTextile Testing Instruments, Testing Equipment Manufacturer

4. The measurement position on the sample; ufpTextile Testing Instruments, Testing Equipment Manufacturer

5. The number of measurements per report on average;

ufpTextile Testing Instruments, Testing Equipment Manufacturer

6. If the two sizes are different, it is necessary to indicate the pore diameter and measurement area of the instrument;

7. Measurement value; ufpTextile Testing Instruments, Testing Equipment Manufacturer

8. For ufpTextile Testing Instruments, Testing Equipment Manufacturer

X's density values and reasons for use ; ufpTextile Testing Instruments, Testing Equipment Manufacturer

9. The measurement of the report Value has a representative standard deviation; 10. Differences with this standard method: ufpTextile Testing Instruments, Testing Equipment Manufacturer

11. Factors that may affect the results of the report results explanation may : ufpTextile Testing Instruments, Testing Equipment Manufacturer

12. Laboratory name and operator name; ufpTextile Testing Instruments, Testing Equipment Manufacturer

13. Recent

calibration certificate or other other Acceptable reference standard block use and traceability. ufpTextile Testing Instruments, Testing Equipment Manufacturer

ufpTextile Testing Instruments, Testing Equipment Manufacturer

X -ray fluorescent analysis thicknesses can provide: coating thickness and element analysis function, which not only excellent performance, but also preferential price. Analyze the thickness and element components of the plating layer at the same time. It only takes a few seconds to obtain accurate measurement results in non -breakdown, and the thickness measurement of the multi -layer coating can also be competent. The lightweight sample room is suitable for different samples of different sizes. It is practical and highly accurate. It is the primary choice for hardware plating, jewelry, terminals and other industries. CUBE series can measure the thickness of various metals, alloy single layers and multi -layers, the content of metal ions in the electroplating fluid, and the content and content of alloy elements. ufpTextile Testing Instruments, Testing Equipment Manufacturer

ufpTextile Testing Instruments, Testing Equipment Manufacturer

ACZET series X -ray fluorescent analysis and measurement characteristics: ufpTextile Testing Instruments, Testing Equipment Manufacturer

Aczeet series X The ray coating thickness measuring instrument is based on ufpTextile Testing Instruments, Testing Equipment Manufacturer

X -ray fluorescent technology . This technology has been confirmed and widely used. analyze. It can analyze solids and liquids. The element A circumference includes TI22 to U92 from the element cycle table, and has a sample compartment of different sizes. ufpTextile Testing Instruments, Testing Equipment Manufacturer

Product Function: 1. Use the X-ray fluorescent spectrum method to measure the metal coating and the thickness of the coverage. The measurement method meets the IOS 16921-2005 standard (equivalent to ISO3497: 2000, ASTM B568 and DIN50987). ufpTextile Testing Instruments, Testing Equipment Manufacturer

1. The range of plating elements: titanium ~ uranium, containing common gold, nickel, copper, silver, tin, zinc, chromium, 钯, etc. ufpTextile Testing Instruments, Testing Equipment Manufacturer

2. Number of plating layers: as many as 5 layers. 3. Measurement point size: circular measurement point, diameter of about 0.2-0.8 mm. ufpTextile Testing Instruments, Testing Equipment Manufacturer

4. Measurement time: Usually 35 seconds-180 seconds. ufpTextile Testing Instruments, Testing Equipment Manufacturer

5. Sample 蕞 Large size: 330 x 200 x 170 mm (long x wide x height). ufpTextile Testing Instruments, Testing Equipment Manufacturer

6. Measurement error: usually less than 5%, and the specific situation of the sample depends. ufpTextile Testing Instruments, Testing Equipment Manufacturer

7. Testing thickness range: usually 0.01 microns to 30 microns, the sample composition and coating structure depends. ufpTextile Testing Instruments, Testing Equipment Manufacturer

8. Measure 8 elements at the same time. ufpTextile Testing Instruments, Testing Equipment Manufacturer

9. Qualitative appraisal materialRen 20 elements. ufpTextile Testing Instruments, Testing Equipment Manufacturer

Product parameter: ufpTextile Testing Instruments, Testing Equipment Manufacturer

ufpTextile Testing Instruments, Testing Equipment Manufacturer

X -ray light pipe

Micro-focus, high performance, tungsten target, scorching size 0.2-0.8mm ufpTextile Testing Instruments, Testing Equipment Manufacturer

· High voltage 50 kV (1.2 mAh) can be optimized according to software control control optimization optimizations can be optimized according to software control. ufpTextile Testing Instruments, Testing Equipment Manufacturer

· The detector high -resolution gas proportional detector · The diameter of a single fixed permeability 0.3mm ufpTextile Testing Instruments, Testing Equipment Manufacturer

· Sample Warehouse 330 x 200 x 170 mm Sample table manual Z axis sample table ufpTextile Testing Instruments, Testing Equipment Manufacturer

· · · · · · · ·Power 230VAC, 50 / 60Hz, 120W / 100W ufpTextile Testing Instruments, Testing Equipment Manufacturer

· Instrument size 350 x 420 x 310 mm ufpTextile Testing Instruments, Testing Equipment Manufacturer