GJB128A test method is to establish semiconductor devices to liquid discharge (ESD) Classification procedures for damage or degeneration sensitivity. This classification is a suitable packaging and operation requirements in accordance with the GJB 33A regulations, and provides classification data that meets the requirements of GJB 1649.
At the same time, meet the test criteria: > IEC61000-4-2; IOS17626.2; GJB128A; GJB1649; GJB548A; IOS19951 ;IEC 61000-6-1;IEC 61000-6-2;IEC 61326;IEC 61340-3-1;EN 61000-6-1;EN 61000-6-2;EN 61326;ITU-T K.20;ISO 14304; Bellcore Gr-1089-Coreansi/ESD STM5.1; ANSI/ESDSTM5.2; IBC747-1; Jedec EIA/JESD22; MIL-STD-750; mil-std-883e/f; ISO14304; GR 1089.
Test Purpose: > The main simulation of the human body or utensils of the human body interference and destruction of the equipment is used to evaluate the electronic equipment Anti -static destruction . >
Australian electrostatic discharge generator has the following characteristics: >
ESD-0220C static discharge generator is completely complete Meet the tester requirements for IEC61000-4-2 standards. Its large static discharge voltage can reach 30kV, which can be used for most electrical and electronic equipmentStatic discharge test ; and it can ensure the comparability and reproduction of the test. The easy -to -replace the blocking kit can easily perform three modes of IEC mode, HBM mode and MM mode, which is suitable for static discharge tests of various semiconductor devices, electronic lines and equipment. The instrument has the advantages of stable performance and convenient use; and meets relevant standards such as IEC, EN, GB. >
Working performance: Discharge stability, and the air discharge voltage is maintained for more than 5 seconds, which is really fully met the standard. > Structure compact:
The whole machine is lightweight (about 4kg), and the structure is small and beautiful. > Complete function:
IEC voltage, the host automatic trigger mode, the voltage gradually scan, positive and negative circulation switching, user self -programming and other intelligent functions. >
Precise discharge: The air discharge mode meets the standard requirements (the voltage is maintained for more than 5 seconds), which is the same as European and American products. The discharge is basically not affected by the humidity of the air, and the discharge is repetitive. The industry's lightweight loading gun is very small with radiation interference, which makes the test process very easy. >
High cost performance:The main device is imported, with high accuracy and low failure rate. Domestic -produced reports reported by the National Appraisal Committee (CNAS) > Static discharge generator . >
Main technical parameters:
1. Output voltage : 0.1 ~ 20.0kv ± 5 % >
2. Voltage polarity: Positive or negative3, trigger mode: single single; COUNT discharge according to the set discharge; 20pps 20 times / second;
4. Test function: built -in IEC level,
5, discharge discharge Mode: contact or air gap
; discharge interval: 0.05 ~ 9.99s (when 20pps mode, the discharge interval is 0.05s)
6. Digger: 1 ~ 9999 (used for discharge times count) 7. Dry capacitor: 150pf ± 10 % (standard configuration; special requirements can be customized) >
8. Drying resistance: 330Ω ± 10 % (standard configuration; special requirementscustomized)
Balm -shaped air gap discharge electrode10. Use environment: Environmental temperature: 10 ℃ ~ 35 ℃ Relative humidity: 30 % to 60 %
11. Power: Single phase AC85 ~ 265V, 50 / 60Hz
12. Weight: about 4kg