This device may be used to test the lights of automobile and auto-bikes, the function of rain sweeper, weather strip, the panel of auto-bikes, and the guiding device of the missiles in national defense system, and the cone shaped cap of radar. It may also be used to test the rainproof function of the equipment used in aviation industry.sJrTextile Testing Instruments, Testing Equipment Manufacturer
sJrTextile Testing Instruments, Testing Equipment Manufacturer
Feature>sJrTextile Testing Instruments, Testing Equipment Manufacturer
The water flow gage is adjustable. It is generally suitable for a rainfall of 10 cm/h and it can meet the requirements of maximum rainfall of 35 mm/m that may happen in the forthcoming 20 years.sJrTextile Testing Instruments, Testing Equipment Manufacturer
The unique water dispenser may steadily control the flow of rainfall and the pressure.sJrTextile Testing Instruments, Testing Equipment Manufacturer
RS may be separately controlled and therefore, it may be replaced without the necessity of having the operator enter the tank to do the work. The new design to eliminate water hammer.sJrTextile Testing Instruments, Testing Equipment Manufacturer
Inverter motor pump, saving more than 50%.sJrTextile Testing Instruments, Testing Equipment Manufacturer
Distance from the nozzle to the test substance adjustable 0(400) ~ 400 (800) mm.sJrTextile Testing Instruments, Testing Equipment Manufacturer
R1, R2, S1, S2 worlds first automatic control system, without having to manually adjust the flow and pressure, and can be instantly switched.sJrTextile Testing Instruments, Testing Equipment Manufacturer
sJrTextile Testing Instruments, Testing Equipment Manufacturer
Specification>sJrTextile Testing Instruments, Testing Equipment Manufacturer
MODEL ITEM |
STD-9710A |
STD-9710B |
INSIDE DIMENSION |
1000x1000x1000(WxDxH) mm |
OUTSIDE DIMENSION |
1450x1300x2000(WxDxH) mm |
TEST TEMPERATURE |
ROOM TEMPERATURE |
RT~85oC(B.P.T.) |
RAIN(SPRAY) |
CAPALITY |
R1 |
Min 1.8 l /minuarr; |
R2 |
Min 3.2 l /minuarr; |
S1 |
Min 24.5 l /minuarr; |
S2 |
Min 39.2 l /minuarr; |
PRESSURE |
R1 |
0.1 kgF/cm2 |
R2 |
0.3 kgF/cm2 |
S1 |
1kgF/cm2 |
S2 |
3 kgF/cm2 |
TEST SPECIMEN FRAME (RPM) |
ADJUSTABLE to 17 RPM |
SPRAY NOZZLE ROTATION SPEED |
23 RPM |
POWER SOURCE |
220V SINGLE PHASE 3KVA |
220V SINGLE PHASE 5KVA
MODEL ITEM |
STD-9710A |
STD-9710B |
INSIDE DIMENSION |
1000x1000x1000(WxDxH) mm |
OUTSIDE DIMENSION |
1450x1300x2000(WxDxH) mm |
TEST TEMPERATURE |
ROOM TEMPERATURE |
RT~85oC(B.P.T.) |
RAIN(SPRAY) |
CAPALITY |
R1 |
Min 1.8 l /minuarr; |
R2 |
Min 3.2 l /minuarr; |
S1 |
Min 24.5 l /minuarr; |
S2 |
Min 39.2 l /minuarr; |
PRESSURE |
R1 |
0.1 kgF/cm2 |
R2 |
0.3 kgF/cm2 |
S1 |
1kgF/cm2 |
S2 |
3 kgF/cm2 |
TEST SPECIMEN FRAME (RPM) |
ADJUSTABLE to 17 RPM |
SPRAY NOZZLE ROTATION SPEED |
23 RPM |
POWER SOURCE |
220V SINGLE PHASE 3KVA |
220V SINGLE PHASE 5KVA |
|
Get a Quote
Your email address will not be published. Required fields are marked *