Welcome to Qinsun Instruments Co., Limited.
2023-05-16 0 Views

Analysis of common failures of liquid level gauges with magnetic flap

Magnetic flap level gauges often experience failures in the actual application process and the reasons for these failures are varied, some are caused by the failure of a single component, others are caused by the failure of multiple components at the same time. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


Next, the most common faults and causes of the magnetic flap level gauge in the application process are analyzed as follows: 0SlTextile Testing Instruments, Testing Equipment Manufacturer


Fault 1. On-site display analysis of abnormal causes of a normal long-distance transmission:0SlTextile Testing Instruments, Testing Equipment Manufacturer


In general, there are many reasons for this error, and the following are the most common reasons:0SlTextile Testing Instruments, Testing Equipment Manufacturer


1. Resistance welding. 2. The pressure exceeds the rating, resulting in damage to the switch. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


3. The glass tube reed switch for home use is fragile, and the reed switch is short-circuited or open, causing the long-distance transmission abnormality. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


4. When the temperature of the medium is too high, the metal sheet will heat up and expand, and the metal contact gap of the dry reed switch is small, so it is easy to occur in the closed state. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


0SlTextile Testing Instruments, Testing Equipment Manufacturer


Error 2. The remote transmission and magnetic flap do not move. This error phenomenon is usually caused by the anomaly of the float. The main phenomena are as follows:0SlTextile Testing Instruments, Testing Equipment Manufacturer


Because the float is damaged, resulting in incorrect reading on the display panel and damage of the float in the liquid level gauge with magnetic flap. This can usually be due to the following reasons:

0SlTextile Testing Instruments, Testing Equipment Manufacturer


1. Due to the incorrect design of the strength of the float, it causes it to sag inward and be deflated under pressure. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


2. The weld is not penetrated or leaking, so the weld will rupture when the float is pressurized and the float enters the water.


3. The float cannot be used normally due to long-term use or demagnetization after long-term use at high temperatures. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


4. Because the magnet steel in the float is loose, the float cannot work normally. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


0SlTextile Testing Instruments, Testing Equipment Manufacturer


Error 3. Because the float is stuck, the reading on the display panel is inaccurate and the float in the magnetic level gauge is stuck. The most common reasons are as follows:
0SlTextile Testing Instruments, Testing Equipment Manufacturer


1. The ambient temperature is too low and the float cannot move normally due to the freezing of the medium. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


2. The installation angle of the buoy is less than 87 degrees. Since the buoy is tilted, the up and down movement of the buoy will be affected. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


3. The float magnetically absorbs iron filings or other debris, causing the float to get stuck and unable to move normally. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


4. Due to poor sealing, the float remainsmer hanging through the infiltrated impurities, so that the swimmer can neither rise nor fall. 0SlTextile Testing Instruments, Testing Equipment Manufacturer


So-called finding the cause of the error is half the solution. Through the above analysis of the most common errors of the magnetic flap level gauge, we have basically found a way to deal with the problem and can take targeted action according to the errors and their causes. 0SlTextile Testing Instruments, Testing Equipment Manufacturer

0SlTextile Testing Instruments, Testing Equipment Manufacturer