Shanghai Qianshi Analysis high and low temperature aging box must avoid during use

Many customers don't know how to maintain the high and low temperature aging box at the first purchase. The following summarizes some things not to do while using the high and low temperature aging box. After reading this article, remember to avoid the foreheadhg4Textile Testing Instruments, Testing Equipment Manufacturer

and not near the heat sourcehg4Textile Testing Instruments, Testing Equipment Manufacturer

. Generally, when placing the high and low temperature aging box, 60-70cm should be reserved maintenance space on both sides to facilitate the cooling of the aging box in high and low temperature. Also be careful not to put it together with some heaters, so as not to increase the power consumption of the high and low temperature aging box. hg4Textile Testing Instruments, Testing Equipment Manufacturer

Second, the opening time of the high and low temperature aging box should be short. In the event of a power failure, you should not rush the door of the high and low temperature aging boxcurrently open. hg4Textile Testing Instruments, Testing Equipment Manufacturer

Third, the ambient temperature difference should not be too large.hg4Textile Testing Instruments, Testing Equipment Manufacturer

If the temperature difference in the use environment is too large, a large amount of water vapor will be generated by the high and low temperature aging box during use. Over time, this will accelerate the corrosion of components, which can easily damage the high and low temperature aging box. hg4Textile Testing Instruments, Testing Equipment Manufacturer

Fourth, do not disable the high and low temperature aging box.hg4Textile Testing Instruments, Testing Equipment Manufacturer

Many customers put the device into a sleep state when the high and low temperature aging box is not used temporarily to save electricity. In fact, because the evaporator of the high and low temperature aging box is mostly made of aluminum products, this is unscientific and likely to affect the service life of the high and low temperature aging box. and the organic matter on the aluminum wall becomes smold and decay, corroding the aluminum plate and damaging the cooling system. Because the plastic of the inner tank is more likely to age at room temperature than at low temperatures, do not let it age, so high and low temperature aging box will no longer work. When you no longer need to use the high and low temperature aging box, you need to defrost it, clean it, and put it in a ventilated and dry place to avoid direct sunlight. Turn on the high and low temperature aging box once a month, let the compressor run normally for half an hour to an hour, and then turn off. hg4Textile Testing Instruments, Testing Equipment Manufacturer

Fifth, do not change frequentlyhg4Textile Testing Instruments, Testing Equipment Manufacturer

The temperature in the general office in winter is about 0-20 °C, and the working temperature of the high and low temperature aging box is relatively high. Components are likely to be damaged during transitions between high and low temperatures. hg4Textile Testing Instruments, Testing Equipment Manufacturer