This test stand, meets ISO 16332,SAE J1488 and SAE J1839 standards, is an unattended automatic system for testing fuel /water separators on diesel engines.kqVTextile Testing Instruments, Testing Equipment Manufacturer
kqVTextile Testing Instruments, Testing Equipment Manufacturer
This system uses automatic injection, sound wave degradation and titration system, with high precision and high reproducibility.kqVTextile Testing Instruments, Testing Equipment Manufacturer
kqVTextile Testing Instruments, Testing Equipment Manufacturer
kqVTextile Testing Instruments, Testing Equipment Manufacturer
Application>
Items |
Parameters |
Flow range |
1-25 Lpm |
Flow precision (double flow meter) |
0.1% |
Temperature control |
plusmn;2ordm;C |
Static pressure control |
0-140 kPa plusmn;14 kPa (0-20 psig plusmn;2 psig) |
Pressure difference control |
1-260 hPa plusmn;1 hPa (0-4 psi plusmn;0.15 psi) |
Fuel tank capacity |
325 L |
Fuel tank export configuration |
SAE amp; ISO |
Tank capacity |
15 L |
Box and poping materials |
Stainless steel |
Bleaching earth modulation circuit |
Included |
Optional fuel preparation |
75 L,Attached bleaching earth treatment system |
kqVTextile Testing Instruments, Testing Equipment Manufacturer
kqVTextile Testing Instruments, Testing Equipment Manufacturer
Circuits analysis>
Items |
Parameters |
Auto-injection amp;Auto-titration |
Real-Time Results |
Reproducibility |
2%plusmn;0.1% |
Water content titration measurement system |
Reproducibility 0.3% |
kqVTextile Testing Instruments, Testing Equipment Manufacturer
Water circuits>
Items |
Parameters |
Ionic water supply rate |
0.9 Lpm |
Metering pump injection |
Automatic Accurate proportional control |
Injection rate |
1.0-576 mLpm |
Filter grade |
30 ppm @ 25 Lpm w/ drainage |
Optional water collection car |
75 L |
kqVTextile Testing Instruments, Testing Equipment Manufacturer
UI,Controller and DAS>
Items |
Parameters |
CPU |
Dell OptiPlex w/ Intel Coretrade; Processor |
Operation sytem |
Microsoft Windows 7 |
UI |
22quot; LCD Display,Keyboard and Mouse |
I/O Hardware Platform |
CompactRIO |
Application |
Custom NI LabView executable w/ graphical displays,满足 ISO 16332, SAE J1488 amp; SAE J1839 procedures |
Data Output |
Output test reports,xlsx files in tables and charts |
kqVTextile Testing Instruments, Testing Equipment Manufacturer
Operating Requirement>
Items |
Parameters |
Power Supply |
480 Vac/3Ph/ 60Hz/25A (International Voltage Available) |
Tap-Water |
1.0 Lpm @ 400-700 kPa (.26 gpm @60-100 psig) |
Colling Water |
Customization |
Compressed Air |
0.14 m3/min @ 550 kPa (5 cfm @ 80 psig), Dry and Oil free |
Ventilation Installation |
150mm (6quot;) Connect |
Environment Temperature |
10-40 ℃ (50-104℉) |
Noise Output |
82 dBA |
Get a Quote
Your email address will not be published. Required fields are marked *