Can the universal traction machine measure T-peel strength? How to test?

The universal tensile machine can be used to test T-peel strength.T-peel strength is mainly a method of testing the peel strength of adhesive flexible materials to flexible materials. The instrument used by our company to test T-peel strength is DSL series universal tensile machine. Let me introduce you how to test it. CjfTextile Testing Instruments, Testing Equipment Manufacturer


CjfTextile Testing Instruments, Testing Equipment Manufacturer

T-Peel Adhesion Test Method CjfTextile Testing Instruments, Testing Equipment Manufacturer

1. This test method specifies Describes the T- Peel test apparatus, sample preparation, test procedure, and treatment of test results for flexible material-to-flexible bonded samples. CjfTextile Testing Instruments, Testing Equipment Manufacturer

2. This test method is suitable for determining the T-peel resistance of the adhesive under specified conditions for adhesive samples consisting of two identical or different flexible materials. CjfTextile Testing Instruments, Testing Equipment Manufacturer


CjfTextile Testing Instruments, Testing Equipment Manufacturer

3. T-Peel Adhesion Test Test Principle CjfTextile Testing Instruments, Testing Equipment Manufacturer

T-Peel Test from Flexible Material to Flexible Material Bond Apply a peel force to the unbonded end of the sample to pull the sample along the bonded line, and the angle between the applied force and the glued line does not need to be controlled. CjfTextile Testing Instruments, Testing Equipment Manufacturer


CjfTextile Testing Instruments, Testing Equipment Manufacturer

4. T-type peel strength testtesting device CjfTextile Testing Instruments, Testing Equipment Manufacturer

4.1 peeling test deviceCjfTextile Testing Instruments, Testing Equipment Manufacturer

DSL series universal traction machine has a suitable load range, and the chuck can separate at a constant speed and apply a pulling force. The device must be equipped with a robust measuring system and display recording system. The force display error is not more than 2%, and the response time of the whole device should be short enough not to affect the accuracy of the measurement, that is, the applied force can be measured when the bonded sample is damaged. The breaking load of the sample soShould be between 10% and 80% of full standard load. CjfTextile Testing Instruments, Testing Equipment Manufacturer

Recommended usage: National Instruments DLS Series Universal Traction Machine, the device parameters are as follows: CjfTextile Testing Instruments, Testing Equipment Manufacturer

a. Load range: 0-500N (optional configuration 30N 50N 100N 200N 500N) CjfTextile Testing Instruments, Testing Equipment Manufacturer

b. Accuracy: The display error of the level 1 force value is not less than 1%. CjfTextile Testing Instruments, Testing Equipment Manufacturer

c. Resolution: 0.01N CjfTextile Testing Instruments, Testing Equipment Manufacturer

d. Loading speed: 0-500mm/min) can be set as desired CjfTextile Testing Instruments, Testing Equipment Manufacturer

e.g. Pattern width: ≤30mm CjfTextile Testing Instruments, Testing Equipment Manufacturer

f. Stretch stroke: 500mm CjfTextile Testing Instruments, Testing Equipment Manufacturer

g. Standard pressure roller: 2000g ± 50g CjfTextile Testing Instruments, Testing Equipment Manufacturer

h. The length of the test plate is 125mm ± 1mm, the width is 50mm ± 1mm, and the thickness is 1.5-2.0mm. CjfTextile Testing Instruments, Testing Equipment Manufacturer

4.2 Peel Test Chuck CjfTextile Testing Instruments, Testing Equipment Manufacturer

The chuck can firmly clamp the sample and remove the pressure device. In order to obtain uniformity over the entire bonding surface, the pressure plates should be parallel to distribute the pressure. If this is not possible, the press plate should be includedbe covered by the elastic seal. The thickness of the gasket is 10mm, and the hardness (Shore A) is about 45. At this time, it is recommended to apply a pressure of up to 0.7MPa. Another method of sample preparation is to glue two plates of appropriate size into an enlarged sample, and then cut the sample from the enlarged sample. When cutting, cutting heat and mechanical force should be minimized. For the effect of sutures, the outermost 12mm wide strip section of the enlarged specimen parallel to the long side of the specimen shall be removed. The average thickness of the adhesive layer of the sample was determined. CjfTextile Testing Instruments, Testing Equipment Manufacturer

4.3 Number of peel samples CjfTextile Testing Instruments, Testing Equipment Manufacturer

The number of samples for each batch number must not be less than five. CjfTextile Testing Instruments, Testing Equipment Manufacturer

5. State Adjustment and Testing Environment CjfTextile Testing Instruments, Testing Equipment Manufacturer

The pattern should be adjusted and tested in the standard environment specified in GB 2918. DThe time for the probe to adjust the state should not be less than 2 hours. CjfTextile Testing Instruments, Testing Equipment Manufacturer

6. T-Peel Adhesion Test Test Method CjfTextile Testing Instruments, Testing Equipment Manufacturer

Separate the unglued end of the flexible test piece and clamp it symmetrically into the upper and lower holders. The clamp cannot slip to ensure that the applied tensile force is evenly distributed across the specimen width. Start the testing machine so that the upper and lower grippers are separated at a speed of 100 ± 10 mm/min. The peel length of the sample must be at least 125 mm, at the same time the recorder records the peel load curve. And pay attention to the type of damage, i.e. adhesion damage, cohesive damage or damage from stickies. CjfTextile Testing Instruments, Testing Equipment Manufacturer

7. Processing of peel test results CjfTextile Testing Instruments, Testing Equipment Manufacturer

For each sample, measure the average peel force from the relationship curve between peel force and peel length and useN is the unit. The peeling length for calculating the peeling force must be at least 100 mm. But with the exception of the first 25mm, the average peel force can be obtained by drawing an estimated contour line or by planimetry.